Description

The NORDISCAN-PL series Scanners are intended for fully automated off-line ultrasonic examination of body and edges of plates, coils, slabs, and ingots. NORDISCAN-PL systems are designed to perform fully automatic high performance inspections of flats outside of the production line on a charging table. The system utilizes our advanced software and displays the defect map in real-time mode, and simultaneously saves the results on a local or external drive for further evaluation, re-evaluation and analysis.

The NORDISCAN-PL series achieves multiple inspection tasks:
Detection of internal imperfections in rolled plates, ingots, and slabs such as: laminations, non-metallic inclusions, porosity, shell, sponge, etc.;
Detection of surface and sub-surface defects;
Detection of zones of mechanical properties uniformity (Hard Sports);
Precise wall thickness measurement;
Plate Geometry Monitoring.

Main Ultrasonic Testing Parameters
Test Sensitivity:
For internal imperfections: equal to FBH 2*;
For surface imperfections: equal to notches 0.2 mm x 10 mm (D x W);
Wall thickness measurement accuracy: +/- 0.05 mm;
Capacity of Testing: 200 s
(calculated for plate 4 m x 12 m).
*Depending of material to be tested

Type of Applied Multichannel Ultrasonic or Eddy Current probes
Non-contact array probes, based on the EMAT;
UT phase array probes;
UT probes with the array of piezo-crystals;
Eddy Current probes;
High-resolution 2D or 3D Laser profilers.

Typical Specification of Plates to be Tested:
Width: 1000 mm – 6000 mm;
Length: from 1000 mm;
Thickness Range: 3 mm – 350 mm;
Material: carbon steel, stainless steel, aluminum, titanium, cooper and alloys;
Surface Temperature: up to 250 deg. C.

Ultrasonic Testing Standards:
Density of Ultrasonic examination, test procedures, acceptance criteria, data processing and representation adhere to multiple international and local standards such as: GOST 22727, SEL 072, ISO 12094, API 5L, ASTM 435, ASTM 578, DNV-OS-F101, EN10160, JIS0901, JIS0801, ISO10893, ISO3183.
Testing and acceptance criteria can be customized based on client specific needs and new standards.