Fixed Clamp on Flow Meter to monitor volumetric flow rate, mass flow rate, energy (heat quantity) flow rate using non-invasive ultrasonic transit time technology
Coltraco Permaflow
Description
The Permaflow is a fixed, clamp-on flow & heat meter. It uses complete non-invasive technology meaning sensors can be positioned on the outside with no need to drill holes or adapt the system in any way, reducing cost, downtime and increasing ease of setup. Being a very flexible platform with numerous bolt-on options, accessories and applications, it offers an ideal solution for measuring the flow rates of most liquids with gas/solid content less than 10% of volume.
Fixed ultrasonic flow meter features
VERSATILE
Capable of working on pipes DN15 – DN 2500; virtually any clean liquids; on a wide range of pipe materials. Without contact with the fluid, there are also fewer issues with the flowmeter being damaged by the nature of the fluid it is measuring compared to inline flowmeters
ACCURATE
Capable of measuring flow velocities between 0.01 m/s – 25m/s. Resolution of 0.25mm/s
RELIABLE
Wall mounted and fixed therefore suitable for conducting measurements in a wide variety of poor conditions as the equipment is affixed firmly to the wall
LOW COST
No installation costs such as drilling into pipes, therefore no downtime to the pipe network is present. Only one individual is required to operate the instrument
Key benefits of ultrasonic flow meter
ACCURATE
Accurate to +/- 0.5% under ideal conditions. Repeatability of 0.15% of measured value
MONITORING
24/7 flow rate monitoring and alert is available
ROBUST
Sensors rated IP66. Sensor temperature range -20°C to +150°C
INTUITIVE
Unique Human Machine Interface (HMI) driven menu emphasises userfriendliness
Datalogging & Communications Ready
16 MB datalogger included as standard – all measurement values can be logged
Serial Communications RS232 and USB included as standard, can be used for device control (command line interface) and datalogger download via PC
4 – 20 mA, Digital, Modbus, Relay, OPTO, Open Collector Output available as optional plug-in modules
Optional Plug-in Modules
- PT100 Thermometer Input (for heat metering applications)
- 4 – 20 mA Current Input
- 4 – 20 mA Current Output
- Digital InputModbus RTU
- Relay Output
- OPTO Output
- Open Collector Output
OSCILLOSCOPE
Built-in signal oscilloscope for sensor positioning and diagnostics to achieve maximum accuracy with the measurement while providing visibility of the potential issues
COMMUNICATIONS
Connection to PC available as standard using both RS232 and built-in USB as well as 4 – 20 mA inputs which is available as an optional plug in
TOTAL FLOW
All measured values can be totalised giving total flow rate measured during a particular measuring session
RECOMMENDED APPLICATIONS
Commercial building heat metering, fuel montoring, waste water and many more
HEAT METERING