rfs@rfsales.com.au
+61(0)2 9545 4433

JAYMI Yoke

JAYMI Yoke

Lightweight electromagnetic yoke

Request a Quote

Description

The JAYMI is the next generation of yoke from Johnson & Allen – Developed to be light weight but powerful, efficient and robust. Previously customers have had to compromise on either weight, durability or power when choosing a yoke. Overcoming these limitations was the design philosophy behind the JAYMI.

The core is housed within an ergonomic injection moulded shell made from an abrasion and chemical resistant plastic and the yoke incorporates a number of rubber gaskets to retard fluid ingress. The energising micro switch is trigger mounted with a rubber membrane making it easy to press and giving a user friendly action to it.

Available in 230V and 110V versions.

 

Product Data

Model JAYMI – 230V JAYMI – 110V
Input Supply
(Unloaded)
230VAC @ 1.3A 110VAC @ 2.3A
Voltage Regulation ±10% of nominal ±10% of nominal
Frequency 50 / 60 Hz 50 / 60 Hz
Waveform AC AC
Switch Position Trigger Mounted Trigger Mounted
Recommended Pole Spacing 135mm 135mm
Pole Spacing Range 60 to 210mm 60 to 210mm
Leg / Pole Contact Size 20 x 20mm 20 x 20mm
Duty Cycle 25% – Max. ON time 30 seconds 25% – Max. ON time 30 seconds
Lift Strength
(100 to 150mm spacing)
> 4.5 kg
(Equivalent to 44 N)
> 4.5 kg
(Equivalent to 44 N)
Magnetic Field* > 2.5 kA/m
@ 6 inch / 152mm spacing
> 2.5 kA/m
@ 6 inch / 152mm spacing
Dimensions (LWH) 260 x 50 x 190mm 260 x 50 x 190mm
Weight 2.30 kg 2.30 kg
Ingress Protection IP56 IP56
Mains Lead 3 Meters 3 Meters
Plug Type ‘C’ Form – 16A ‘C’ Form – 16A
Warranty 12 Months 12 Months
Conformity UKCA
CE
RoHS
UKCA
CE
RoHS
Specification Compliance

(List is not exhaustive)

ISO 9934: 2016
ASTM E 1444-22a
ASTM E 709-21
ASTM E3024-22a
ISO 9934: 2016
ASTM E 1444-22a
ASTM E 709-21
ASTM E3024-22a
Powerbelt Compatibility No Yes

 

*Note: The tangential extraneous magnetic field will vary depending on whether the yoke is energized in free space (unloaded) or when in contact with a part (loaded). Material properties and pole spacing will also alter the magnetic field. For this reason operators should not rely on field measurements alone as a performance check and should verify the lifting strength of the yoke with a 4.5kg test weight and use a QQI shim or flux indicator strip for evaluation before undertaking inspection.