rfs@rfsales.com.au
+61(0)2 9545 4433

Graetz Doserate Measuring System X 5 CEx

Graetz Doserate Measuring System X 5 CEx

Dose rate meter with alarm function for personal radiation protection and dose rate detection when handling ionising radiation in explosive atmospheres, with connection facility for the gamma probe 18550CEx.

Request a Quote

Description

Doserate Measuring System X 5 CEx

for the use in  explosion-endangered atmospheres 

Please note: The X 5CEx optically corresponds to the doserate meter GRAETZ “X 5 C plus“.

    • PTB-approved doserate meter for measuring gamma radiation and X-rays
    • measuring size: ambient doserate equivalent H*(10)
    • detector: energy compensated Geiger-Müller-tube
    • large digital indication of measured values on LC display (illuminable)
    • additional quasi-analog doserate indication (3,5 decades, logarithmic bar graph)
    • indication of peak and average value of doserate
    • 4 free programmable dose and doserate alarm thresholds
    • automatic or manual storage of dose and doserate values together with date and time
    • indication of residual time for staying in the current radiation field with regard to the maximum allowed dose
    • switchable acoustic single-pulse indication
    • menu driven operator guidance for easy operation, partly secured by password
    • storage of set parameters also when device is switched off or during battery replacement
    • continuous self testing and monitoring ensures high reliability
    • metallized, compact housing of high impact-proof plastic (easily to decontaminate), sealed for submersion up to 1 m depth (IP 67)
    • power supply by firmly installed accumulator
    • automatic probe identification
    • EMC-proof
    • Absolutely necessary accessories:
    • – recharger “461L” for recharging the built-in accumulator

    • Optional accessories:
    • – probe

“18 550 CEx”

    •  for measurements at “hard-to-get-to” places
    • – probe cable “CEx”, length: 1,25 m – not extendable
    – leather bag “D” for accommodating the basic unit, the probe and the cable
   

Basic unit X 5 CEx

 

 

Probe 18 550 CEx

 

Doserate measuring range:  

1,0µSv/h – 20 mSv/h

 

 

10µSv/h – 20 mSv/h

 

Doserate indication range:  

0 nSv/h – 20 mSv/h

 

Dose indication range:  

0 nSv – 10 Sv

 

Energy range:  

40 keV – 1,3 MeV

 

 

75 keV – 1,3 MeV

 

Doserate alarm thresholds:  

4, free programmable, 0µSv/h – 20 mSv/h

 

Dose alarm thresholds:  

4, free programmable, 1µSv – 10 Sv

 

Temperature range:  

-20°C up to +40°C

 

Power supply:  

9V-accumulator (firmly installed)

 

 

from the basic unit

 

Dimensions / Weight:  

(152 x 82 x 39) mm

approx. 475 g

 

 

diameter=40 mm, length=126 mm

approx. 250 g

 

PTB-Approval No.:  

23.51/05.02

 

 

none

 

ATEX-Approval No.:  

BVS PP 04.2028 EG

 

Marking:  

  II 2G EEx ib II BT6; I M2 EEx ib I  

 

 

Go to Top