Twin nickel-chrome test panels for checking comparative penetrant system performance.
NiCr Test Panels
Description
NiCr test panels help verify penetrant sensitivity and system performance by comparing working penetrant materials with new, unused materials on identical flaws. The brass panels have a 20 micron nickel-chrome plating stressed to create linear cracks and are supplied as a matched pair.
Application
Checking penetrant deterioration, comparing penetrants and verifying sensitivity or visibility in fluorescent penetrant testing.
Accessories
Supplied as twin test panels
Specifications
Length: 100 mm ± 2 mm;
width: 35 mm ± 2 mm;
thickness: 2 mm ± 0.2 mm;
plating/flaw depth: 20 microns; ISO 3452-3 Type 1 reference block;
standards: AMS 2647D, ASTM E1417 and ISO 3452.