Pipeline Crawlers

Pipeline Crawlers for NDT Radiography in Australia

RF Sales supplies X-ray pipeline crawlers and related radiography equipment to Australia’s non-destructive testing (NDT) industry. The crawlers on this page include the 6CR2, 10CR2, 10CR2S and 24CR2 models, with digital imaging and accessory options. We can also advise on crawler X-ray generators and control units.

Call (02) 9545 4433 or send your pipe size, material and inspection procedure through our enquiry form.

What Pipeline Crawlers Do in NDT Radiography

A radiographic pipeline crawler is a self-powered vehicle that carries a radiation source along the inside of a pipe. It stops at a circumferential weld and positions the source so one exposure covers the full circumference. The weld is inspected from the inside, without cutting into the pipe. Crawlers are used mainly on new pipelines, where the inside of the pipe is accessible.

The source is usually an X-ray generator. Some crawler models can also work with a gamma projector.

Radiography can reveal internal discontinuities such as porosity, inclusions and some forms of incomplete fusion or penetration. What it shows depends on defect orientation, material thickness, exposure geometry and image quality. Your inspection procedure sets the technique, image quality requirements and acceptance criteria.

A crawler is one part of the inspection setup. It works with a radiation source, controls and a power supply. If you use film radiography, you may also need compatible film, cassettes and lead intensifying screens.

Pipeline Crawler Models

The crawlers listed on this page are JME models. The pipe sizes below are the manufacturer’s published internal diameter ranges. Confirm the current specification for your application before you order.

Model Pipe internal diameter Notes
6CR2 5.5 to 18 in (140 to 457 mm) Compact and lightweight. Used with X-ray generators.
10CR2 9.5 to 48 in (240 to 1220 mm) Works with X-ray generators from several manufacturers. It can also work with a gamma projector.
24CR2 22 to 60 in (558 to 1524 mm) Covers larger pipe sizes than the other models listed.

The 10CR2S, PXB:wireless, JME:PBU and pipeline crawler accessories are also listed. Enquire for their specifications and compatibility.

The DXB:1 digital X-ray buggy works with the CR2 crawlers and produces panoramic digital radiographs without film.

Operators set up and monitor the CR2 crawlers from a remote handset. JME describes handset functions for pre-deployment setup, live monitoring, an emergency X-ray stop and recovery if the crawler electronics fail.

Crawler X-Ray Generators and Control Units

RF Sales can also advise on crawler X-ray generators and control equipment’s from different suppliers like Comet, Balteau, ICM etc.

Choose a generator against the exposure requirements of your inspection procedure. Check the generator, controller, battery pack and carriage together, because mechanical fit and electrical compatibility both matter. This is especially important if you need replacement components for an existing crawler rather than a complete system.

Crawlers run on a battery pack carried in the carriage. Battery capacity, charging requirements and operating time depend on the full configuration, so confirm them for your equipment and workload before you plan exposures per charge.

How to Choose Pipeline Crawler Equipment for Your Application

Send these details with your enquiry so we can check the full configuration:

  • Internal pipe diameter:confirms clearance for the carriage, generator and battery pack.
  • Material and wall thickness:sets the exposure requirements.
  • Pipe layout:bends, gradients, restrictions and entry points.
  • Inspection procedure:the radiographic technique and image quality required.
  • Existing equipment:carriage, generator, controller and battery specifications.
  • Operating conditions:temperature, pipe condition and expected travel distance.
  • Workload:the number of weld exposures and your charging arrangements.
  • Recovery provisions:how equipment is retrieved if movement or power is interrupted.

Assess the full configuration rather than selecting a generator independently. View our wider industrial radiography X-ray equipment for related options.

About RF Sales

RF Sales has supplied Australia’s NDT industry since 1993, with locations in Sydney and Perth. Alongside pipeline crawlers, our radiography range includes films and chemicals, scanners and digitisers, and film processors.

Request a Quote for Pipeline Crawlers

Tell us your internal pipe diameter, pipe material, wall thickness and inspection procedure. For replacement or upgrade parts, include the model and power specifications of your existing equipment. Say if you need a complete crawler system or individual generator and control components.

Call Sydney on (02) 9545 4433 or Perth on (08) 6183 6670, or complete our enquiry form to ask about specifications, compatibility, pricing and availability.

Pipeline Crawlers for NDT Radiography FAQs

Are radiographic pipeline crawlers the same as CCTV inspection crawlers?

No. Radiographic crawlers carry a radiation source to inspect welds. CCTV crawlers carry cameras to record visible conditions inside a pipe. They show different things, so they answer different inspection questions.

What pipe dimensions affect crawler selection?

Internal diameter decides which models fit, as the ranges above show. Wall thickness affects exposure requirements. Bends, gradients and restrictions affect how the carriage moves and where it can enter.

Can a crawler generator be fitted to an existing carriage?

It depends on mechanical space, mounting, electrical connections, battery supply and controls. Send the specifications of your existing system before you choose replacement equipment.

Do pipeline crawlers use X-ray or gamma sources?

The CR2 crawlers listed here are used with X-ray generators. JME also states that the 10CR2 can work with a gamma projector. Tell us which source arrangement your procedure requires.

What information should I provide when requesting a quote?

Include pipe dimensions, material, inspection procedure and operating conditions. Say if you need a complete crawler configuration or individual generator and control components.

Go to Top